Protection
Importance of Relay Coordination
Why protective device coordination is critical for both safety and system reliability.
Read MorePROTECTION COORDINATION · UNITED STATES
Protection coordination decides which device clears a fault and how long it takes. Get it wrong one way and a local fault trips the whole plant. Get it wrong the other way and clearing times stretch, which raises arc flash incident energy at every location downstream. In the US both outcomes are assessed by someone: the first by your operations team, the second by an OSHA inspector reading your labels.
Free ConsultationSelectivity and clearing time pull against each other. The study is where that trade-off gets made deliberately rather than by default.
The device nearest the fault should operate first. We grade time-current characteristics through the system so an upstream device holds while the downstream one clears, which is what keeps a local fault local.
WHAT GOES WRONG
Coordination problems usually only reveal themselves during a fault, which is the most expensive possible moment to discover them.


THE OUTCOMES
The deliverable is a settings schedule somebody can actually apply, with the time-current curves that justify it and the arc flash consequence of each choice stated alongside.
Coordination needs load flow and short circuit results first, since grading depends on the fault current available at each device.
Capture every relay and breaker setting as currently applied, including whether instantaneous elements are enabled, rather than taking the design schedule.
Request the serving utility's upstream protection data, because grading has to hold at the service as well as inside the plant.
Develop settings that maintain selectivity, then check the resulting clearing times against incident energy so the trade-off is made explicitly.
A settings schedule with curves, clearing times and arc flash consequences, in a form the site can implement and verify.
Upstream, midstream, and downstream facilities
Hospitals, clinics, and medical campuses
Tier I through Tier IV facilities
Production lines and industrial plants
Generation, transmission, and distribution
Office buildings and retail complexes
Universities, schools, and research labs
Federal, state, and municipal facilities
Protection
Why protective device coordination is critical for both safety and system reliability.
Read MoreSafety
How relay coordination directly impacts arc flash incident energy levels.
Read MoreCompliance
Why coordination studies are an integral part of NFPA 70E compliance.
Read MoreWe help convert your obstacles into innovative solutions. Future-proof your electrical infrastructure with our innovative solutions.