Analyse and Evaluate the Performance of Electric Motors as per UK Regulations

MicrosoftTeams image 32 1

Globally, industrial electric motors are utilized to power a vast array of applications. According to the International Energy Agency (IEA), the automobile industry consumes up to 70% of all industrial energy, 35% of all energy utilized in the commercial and service sectors, and 45% of all electricity produced worldwide. Each hour of downtime caused by a motor failure costs thousands of dollars, demonstrating the importance of electric motors to a variety of industrial operations. 

They are the primary reason why power plants emit greenhouse gases and negatively impact the environment. Also, they are primarily responsible for the significant increase in power demand in developing nations. There is an economic potential on a worldwide scale to enhance the energy efficiency of industrial motors by 20% to 30%, with most payback periods of less than three years. Electric motors are responsible for approximately 15%, or 4.3 billion tons, of the world’s yearly CO2 emissions, which total 26 billion tons. Increasing energy efficiency is one of the most cost-effective and low-risk solutions to reduce greenhouse gas emissions and halt the increase in energy consumption. 

Utilize a motor that functions properly because: 

  • reduced operational expenses. 
  • A longer distance that is cooler and quieter. 
  • greater reliability and longer motor life 
  • Greenhouse gas emissions are being reduced. 

Beginning a Motor Analysis:

Not usually electric motors convert 100% of their power into mechanical energy. Due to friction, windage, and losses in the stator, rotor, and magnetic core, some energy is wasted. Due to these losses, the motor’s performance is deteriorating. 

When you consider how much energy is consumed and how electric motors are utilized in industry, it becomes clear why and how crucial it is to analyze energy efficiency and establish minimum energy performance criteria. 

The accuracy with which efficiency and motor loss are assessed relies on the testing method employed. There is no single testing procedure employed across all industries in the globe. Even though the concept is simple, it might be difficult to quantify and certify the energy efficiency of a motor using the various standards. 

Techniques for Evaluating Effectiveness that are Globally Accepted:

In industrial contexts, the following testing procedures are frequently discussed: 

IEEE 112-2004 is a typical method for testing multiphase motors and generators. 2014, “Methods for calculating the efficiency and losses of rotating electrical machinery,” International Electrotechnical Commission (IEC) Publication 60034-2-1, Tests. 

The Japanese Electrotechnical Committee created the JEC 37 standard for induction devices. IEEE Standard 112-2004 ANSI/IEEE 112-2004 

This technique includes 10 measures to evaluate the efficiency of energy consumption. To select the most essential: 

  • A simple test of input and output 
  • Loss-separated input and output testing. 
  • Back-to-back testing of two interconnected devices. 
  • The load losses are calculated using the smoothed residual losses. 
  • The “Eh-star” technique 

There are three distinct forms of IEC standard testing: 

  • Calculating the input and output power of a single machine. 
  • Monitoring the power entering and leaving two devices that are linked in series. 
  • The losses from a single machine were tallied. 

The Japanese JEC standard 37 test procedures are indifferent to the additional load losses. Businesses may save money and benefit the environment by reducing the energy use of their equipment and appliances. This is only one of the many significant economic and environmental benefits. 