Independent on-site testing of switchgear, transformers, cables, and relays — calibrated equipment, certified engineers, audit-ready reports.

The full electrical condition picture.

Thermographic inspection of switchgear, busbars, and connections

HV testing (Hipot, partial discharge, dielectric withstand)

Switchgear and circuit breaker functional testing

Transformer testing (turns ratio, winding resistance, insulation, dielectric)

Cable diagnostics (VLF, tan delta, partial discharge)

Protection relay testing and secondary injection

What the data tells us.

Inspection and testing under Carelabs is purely advisory. We do not sell switchgear, we do not install equipment, we do not accept OEM commissions on what our findings recommend. Our reports are conflict-free — and that distinction shows up in what we test and how we report it.

Field equipment is calibrated to ISO 17025 traceable standards. Every reading is timestamped, geo-tagged, and tied back to the asset's nameplate data in the report. Anomalies are ranked by criticality with a concrete corrective action — not a brochure for a replacement product.

Deliverables

What you receive.

01

Condition assessment report

Per-asset findings with risk ranking, photos, and timestamps.

02

Thermographic imagery

Raw IR images and side-by-side visible-spectrum reference photos.

03

Test certificates

Calibrated equipment certificates and result records for each asset tested.

04

Recommended actions

Concrete next steps — clean, retighten, replace, monitor — never tied to a vendor.

05

Retest schedule

Cadence recommendations for your maintenance management system.

06

Closeout meeting

Engineer walkthrough of findings with your operations and electrical teams.

Methodology

How we run a campaign.

01

Scope & Site Survey

On-site walk-down, single-line diagram review, nameplate verification, and protective device setting capture by a lead engineer.

Scope · Fee · Named lead
02

Modelling & Analysis

Network rebuilt in industry-standard software. Coupled studies — load flow, short circuit, arc flash, protection coordination.

Validated model · Field data
03

Findings & Mitigation

Every finding ranked by risk, with concrete mitigation paths — relay setting changes, breaker upgrades, PPE labelling.

Risk register · Mitigations
04

Implementation & Verification

Re-issue after commissioning, retest, and sign-off. Closure on paper and on the floor — labelled, documented, signed.

Signed report · Labels
Aligned standards

Field work to your auditors' satisfaction.

IEC 60076IEC 60270IEEE C57IEC 60502ISO 17025NFPA 70BIEC 60076IEC 60270IEEE C57IEC 60502ISO 17025NFPA 70B
Notes & Queries

Common questions.

01

We scope per site after the initial walk-down. A fixed-fee proposal follows within the agreed quoting window with a named lead engineer and a deliverable list.

02

Yes. Deliverables align with NFPA 70E, IEEE 1584, IEC 60364, IEC 61482, ATEX, IECEx, BSI, and AS/NZS, and are issued by certified power systems engineers.

03

Most analytical work is offline from data we capture. Field testing is scheduled around your operations with planned outage windows or live techniques where safe and standards-compliant.

Ready to start the engagement?

Tell us about your project. We come back with a fixed scope, fixed fee, and a named lead engineer.