To make sure that the power system at your facility is reliable, safe, and efficient under both normal and abnormal circumstances, a power system analysis comprises a variety of technical assessments as well as the use of scientific analytical ideas and techniques.  

Understanding how a system would operate in various configurations and how interruptions like the switching of a capacitor, the starting of a big motor, or the energy from an arc flash will affect it are the goals of a power system analysis. To make sure that safety equipment functions correctly in the case of a short circuit or other issues, a power system analysis could also be required.  

Power systems must be studied to have a steady and reliable electricity supply. A well-designed power system guarantees dependable operation and maximizes plant usage under all operating circumstances. Poorly built systems suffer from failures, flaws, inefficiencies, and diminished safety. 

The vast majority or all of the minor studies listed below may be included in a standard power system analysis: 

  1. Study and investigation of load flow 
  2. Investigation and analysis are done on short circuits. 
  3. An examination of relay interaction 
  4. Analyzing and studying the danger posed by arc flash 
  5. The investigation of harmonics in science 
  6. Study of movement and change 
  7. Earth-related research 

The first three studies will be examined in this blog article. and be aware of the guidelines and techniques used in each of these inquiries. 

Load Flow Analysis and Research:

An electrical network is examined during a load flow study to ascertain the direction of power flow. It helps calculate losses, voltage, current, and power factor and the amount of active and reactive power generated by the power system. 

The load flow study included three parts: 

  • Network and power system component modeling 
  • The formulation of equations for load flow. 
  • Using algebra to calculate the equations shows how load and flow are related. 

There are three ways to get information on the electricity system: 

  • One of the most widely used approaches to data analysis is the Gauss-Seidel System. This strategy has the benefits of being straightforward to apply, using little in the way of processing resources, and accelerating job completion. Sadly, extra steps are required due of the sluggish convergence. The quantity of iterations increases along with the number of buses. 
  • The more complicated Newton-Raphson method makes use of quadratic convergence, which is helpful in situations that are challenging to comprehend. While fewer repetitions are needed to reach convergence, this method uses less computational power. Regulating transformers and slack bus selection have less of an influence, making it even more exact. It may be challenging and takes up a lot of machine memory, which is a drawback of programming. 
  • The Rapid Decoupled Load Flow System (FDLF (Fast Decoupled Load Flow)) is an alternative method for doing load flow analysis. The primary advantage of this method is that it requires less computer memory. It is widely used in place of the Newton-Raphson technique for real-time power grid control since it completes computations five times quicker. This program is only available under certain conditions. As a result, it is more difficult to modify it in the power sector to take flow or system protection into account. 

Short-Circuit Analysis and Investigation:

One or more of the following types of short circuits will be examined during the analysis of short circuits: 

  • When two phases fail at once, it causes a line-to-line fault. 
  • Just one phase hits the ground during a single line-to-ground failure. 
  • Both phases and the ground are simultaneously shorted in a double line-to-ground fault. 
  • A short connects each of the three phases in a three-phase fault. 

It will be easier to draw a one-line diagram of the power distribution system after the problem is determined. Use the generated single-line diagram and an impedance diagram along with numerical values for the utility source, transformer, and conductor in relation to the voltage that each component may use to calculate short circuits. The full-load amps, the transformer multiplier, and the short circuit current are all calculable values. To verify that the power distribution system has the proper safety measures in place at various places to prevent accidents and downtime, it is necessary to compare the results to the equipment ratings. 

Relay Coordination Evaluation:

Relays must operate fast, consistently, and selectively to isolate problems; hence relay coordination is an essential part of power system safety design. To determine how many overcurrent safety devices are needed in a power system, coordination analysis is utilized. It also helps in figuring out the specifications, configurations, and dimensions needed to strike a compromise between safeguarding equipment and limiting the system’s operation. 

Data is collected using software such as ETAP (Electrical Transient Analysis Program), which is used to model the power system. After performing a short circuit analysis, fault currents at each electrical location in the system are measured. 

The selection and design of protection devices therefore reduces the effect of system equipment failures. The time-current characteristic curves of the protective device are monitored and compared to identify locations where coordination has deteriorated. Adjustments are done as needed to ensure that protective devices work reliably and selectively. 

Benefits of Care Labs's services:

  • The electricity grid is becoming more dependable. 
  • using apparatus with the correct power rating. 
  • Electrical risks will be safer and less dangerous. 
  • Follow all applicable laws and installation codes for electrical systems. 
  • Suggestions for enhancing the operation and dependability of the system. 
  • The present status of the power system is documented for any upcoming inspections. 

To monitor the voltage at various buses and the actual and reactive power flow between buses, analyze the system under various fault conditions, and ascertain how well the system handles small and significant changes, Care Labs offers Load Flow study & analysis, Short Circuit study & analysis, and Relay coordination analysis. 

If your business requires a power system analysis in Vietnam, get in touch with us or request a quote. One of our customer care representatives will respond within 24 hours. 

Our Newsletter