Power Quality Analysis

CareLabs evaluates the condition of electricity for Coloumbian enterprises. Our mission is to safeguard your electrical appliances, electrical installations, and electrical equipment from problems caused by erratic power supplies.

Get Your Power Quality Analysis Report Now

Contact our experts for trustworthy solutions suited to your company's needs.

The data collection, monitoring, and instrumentation technology of the present day is utilized by numerous organizations and an increasing number of individuals. Almost no electrical apparatus is designed to withstand the voltage fluctuation spectrum, which is a common characteristic of distributed power. CareLabs can assist with equipment installation, control, protection, and power conditioning concerns 

The Purpose of the Power Quality Analysis Is:

  • Electrical system and load disparities are evaluated.
  • By analyzing the workplace, simulation methods for providing power quality solutions will be enhanced.
  • Estimating the functionality and efficacy of load apparatus
  • Increase the machine’s power factor and reliability.
  • Limit your energy consumption.
  • To prevent issues and disruptions.
  • Reducing anomalies in power quality, such as harmonics, surges, and transients.
  • Assist in the prevention of PLC lockups and voltage/frequency surges.
  • To prevent nuisance tripping, capacitor detonation, and transformer overloading.
  • Reduce dramatically utility costs
  • Extend the lifespan of the network and its components.
  • Check electrical equipment to ensure that it can withstand changes.

Peru Must Investigate Power Quality:

All electrical networks experience supply interruptions, which occur more frequently when cyclones, natural disasters, or accidents damage power lines. The power supply fluctuates frequently. The characteristics of power supplied by an electrical network are susceptible to fluctuations, disturbances, and distortions of three distinct types.

1.A frequency deviates from its normal frequency range when it exceeds it.

2. When the voltage form is maintained but the voltage amplitude is greater than usual, voltage disruptions occur.

2.1 Voltage declines and surges that last less than a minute are examples of short-lived voltage fluctuations.

2.2 Long-lasting voltage fluctuations are under- and overvoltages that persist for more than one minute.

2.3 Unbalanced voltage is the result of unequal load distribution between phases, which causes significant heating of equipment.

2.4 Differences in voltage between neutral and ground

3. Disturbances caused by voltage distortion, which occurs when the voltage’s shape is neither sinusoidal nor uniform.

3.1 Harmonics and inter harmonics contribute to resonance issues, increased losses, device heating, and inefficient utilization of power.

3.2 Transients of short duration that have the potential to damage switch contact surfaces, cause system inefficiency, and accelerate the failure of motor drives and control.

Colombia Must Investigate Power Quality:

All electrical networks experience supply interruptions, which occur more frequently when cyclones, natural disasters, or accidents damage power lines. The power supply fluctuates frequently. The characteristics of power supplied by an electrical network are susceptible to fluctuations, disturbances, and distortions of three distinct types.

1.A frequency deviates from its normal frequency range when it exceeds it.

2. When the voltage form is maintained but the voltage amplitude is greater than usual, voltage disruptions occur.

2.1 Voltage declines and surges that last less than a minute are examples of short-lived voltage fluctuations.

2.2 Long-lasting voltage fluctuations are under- and overvoltages that persist for more than one minute.

2.3 Unbalanced voltage is the result of unequal load distribution between phases, which causes significant heating of equipment.

2.4 Differences in voltage between neutral and ground

3. Disturbances caused by voltage distortion, which occurs when the voltage’s shape is neither sinusoidal nor uniform.

3.1 Harmonics and inter harmonics contribute to resonance issues, increased losses, device heating, and inefficient utilization of power.

3.2 Transients of short duration that have the potential to damage switch contact surfaces, cause system inefficiency, and accelerate the failure of motor drives and control.

What Information Is Included in an Analysis of Power Quality?

Identifying various power quality issues, such as the following, requires multiple techniques:

  • In harmonic analysis, computer algorithms are used to identify and anticipate potential harmonic issues and devise reduction strategies.
  • Analysis of Transients and Surges This investigation will uncover transients and surges.
  • This study will monitor the voltage’s short-term rise and decline, as well as its value and direction.
  • Evaluation of Reactive Force Through this investigation, the preferred reactive power at the distribution and load extremities will be determined.
  • This concept would reduce petroleum consumption and energy surcharges by synchronizing and measuring captive power to meet demand.
  • This analysis predicts voltage levels, losses in system branches, power flow magnitudes, and power factor based on the provided operating conditions.

CareLabs provides the highest caliber of service to enhance the dependability and quality of your electrical system for the benefit of all its clients. Bogotá, Medellín, Cali, and Barranquilla del Mar are among the major locations where we monitor electricity quality. Contact us immediately to schedule a power quality inspection or receive a quotation! 

OUR SERVICES