Motor Start Analysis

Find Out What It's All About

CareLabs provides Swiss-based businesses with specialized Motor start research and analysis services. The primary objective of our motor start analysis service is to evaluate the peculiar consequences of starting a large motor. In addition to correctly connecting an electric motor to the line voltage, there are several additional aspects to examine before starting it, including nuisance tripping, excessive nominal currents, and flickering or fading light, which are all indications of a faulty power supply.

What is Involved

CareLabs will send qualified personnel to your area to collect data on recent and historical motor installations. Then, calculations are performed to predict future consequences, and recommendations for mitigating such effects are provided. These calculations are done with the acquired data and manufacturer input. 

Using both static and dynamic modelling methodologies, motor starting procedures may be evaluated. 

  • The measured starting impedance of the electric motor is modelled to identify the optimal load flow solution.
  • In pre-fault short circuit conditions, the short-circuit technique is utilized for motor starting currents, the voltage drop method is utilized.
  • If an accurate dynamic model of the electric motor circuit and load-torque characteristics are available, the dynamic model of the electric motor may be utilized to estimate the impact of motor starting in a conventional transient stability approach.
  • In the absence of thorough dynamic model information for an electric motor, simulations of transient stability may be utilized.
motor-start-2

A Motor Start Analysis is Required in Swiss:

motor-start-3

Modern industrial systems are more dependent on motors, and the size of electric motors is growing. When a large motor connected to a line is started, it might cause interference with surrounding loads, buses, and the electric motor. When starting an electric motor, the terminal voltage must be at 80% of the rated voltage or higher. Since the square of a motor’s terminal voltage is exactly proportional to torque, voltage difference influences the load torque of the motor.  

Running machines may approach their breaking torque and slow down or halt in the case of a severe voltage fall. Numerous products, including lighting loads, control systems, and electrical equipment, are affected by voltage drops. In addition, a large initial current reduces terminal voltage, hence increasing the current drawn by all systems supplying a continuous load. Furthermore, problematic low-voltage relays are found. 

When Is a Motor Start Analysis Required?

  • Prior to or during the acquisition of a large motor.
  • If there is no available generator and the motor rating exceeds 30 percent of the base KVA rating of the supply transformer.
  • If the motor rating exceeds 10 to 15 percent of the generator’s KVA rating and the generator is the only source of power for the system. A motor start study may be required if many motors start simultaneously in an industrial setting.
  • When starting a motor with a large capacity, the capacity constraints of smaller power supply make voltage loss concerns even more difficult. It is simpler to comprehend the output of systems that employ tiny generators if one examines how motors start up.
motor-start-4

Motor Start Analysis's advantages

motor-start-5

Analysis of a motor’s startup utilizing a motor or starting technique with the optimum speed-torque characteristics is desirable. Any unusual loads must be accelerated under closely monitored conditions to avoid exceeding the equipment’s maximum permissible torque. It is possible to verify that the motor’s shaft is operating at any time by performing a motor start study. As a result, it aids in determining the maximum permitted torque for the apparatus. 

Motor starting research determines if an electric motor can start and accelerate, and the machine’s voltage. The skilled personnel at CareLabs conduct motor start studies to comprehensively evaluate your electric motor. We provide motor start analysis services in every major Swiss city, including Zurich, Geneva, Basel, and Bern. Contact us immediately for price information or to arrange your motor starting study. 