Protective Devices Testing Services

Protective devices are equipment applied to electric power systems to detect abnormal and intolerable conditions and to initiate appropriate corrective actions. These devices include lightning arresters, surge protectors, fuses, and relays with associated circuit breakers.

From time to time, disturbances in the normal operation of a power system occurs. These may be caused by natural phenomena, by falling objects such as trees, by animal contacts or chewing; inadvertent acts by plant maintenance personnel, or other acts of humans; or by conditions produced in the system itself, such as switching surges, load swings, or equipment failures. Protective devices must therefore be installed on power systems to ensure continuity of electrical service, to limit injury to people, and to limit damage to equipment when problem situations develop. Protective devices are applied with the degree of protection desired or felt necessary for the particular system.

Why Protective Device Testing is Done?

Protection systems play a key role for the safe and reliable operation of today’s electricity power systems. Properly working protection devices help to maintain the safety of the system and to safeguard assets from damage. In order to ensure reliable operation, protective relays as well as recloser controls must be tested throughout their life-cycle, from their initial development through production and commissioning to periodical maintenance during operation.

Carelabs equipment is ideal for each of these life-cycle phases and for any environment. As a reliable long-term partner, we offer state-of-the-art testing solutions which are continuously being developed and maintained to help you to keep pace with the increasingly complex requirements of your systems.

How to Conduct Protective Device Testing?

Basic devices have the ability to recognize and define fuses, protective relays, breaker trip devices, and surge suppressors and to understand their differences and uses. A common mistake for relay testers is to use spare outputs, displays, and/or LEDs for their pickup and timing tests and ignore the in-service output logic, believing that they are using the same elements in their test equations as the final logic.

Depending on the protective device the tests varies accordingly:

Low-Voltage Breakers

Solid-state units can be tested by either secondary or primary current injection.

The secondary injection test set allows checking of the solid state trip unit operation without using primary current. The test set will pass enough current to check any desired calibration point. The breaker must be de-energized before checking the operation of the solid-state trip units. If the test set shows that the solid-state trip unit is not functioning properly, the trip unit should be replaced.

The primary current injection method is usually preferred because this method verifies the sensors and wiring, as well as the conduction path in the breaker. It is recommended that the primary injection test be performed simultaneously on all three phases when testing breakers with solid-state trip units. If three phase primary injection testing is not practical, then the sensors and wiring should be tested separately.

These tests are performed per NETA and the National Electrical Manufacturers Association (NEMA) procedures, and in accordance with manufacturer recommendations.

Relays

A relay is an automatic device which senses an abnormal condition of electrical circuit and closes its contacts. There are different types of relays:

Current Relays

Test are made to check that the overcurrent unit operates only when the directional unit contacts are closed.

  • Contact function– Contacts are manually closed (or opened) and observed that they perform their required function, i.e. trip, reclose, block, etc.
  • Pickup – Gradually current or voltage is applied to see that pickup is within limits.
  • Dropout or reset – Current is reduced until the relay drops out or fully resets. This test will indicate excess friction. Should the relay be sluggish in resetting or fail to reset completely, then the jewel bearing and pivot is examined.

Directional and power Relays

Directional overcurrent relaying refers to relaying that can use the phase relationship of voltage and current to determine direction to a fault.

The simplest pickup test for a directional unit is an in-phase test – i.e. current and voltage in phase. This test will eliminate the need for a three-phase supply, phase shifter, and phase-angle meter. However, it is kept in mind that such a test is usually far from the angle of maximum torque (usually 60° lag for ground relays) and thus, small changes in components can yield large variations in in-phase pickup.

Voltage RelaysSecondary Injection Test

  • Measure the relay auxiliary supply to ensure it is within the nameplate rating allowable range.
  • C…

Our Process

Our Process

01

Consultation

We discuss your facility requirements, compliance goals, and project timeline.

02

Data Collection

Our engineers gather system data, single-line diagrams, and equipment specifications on-site.

03

Analysis

We perform the study using industry-standard software and IEEE/IEC methodologies.

04

Reporting

You receive actionable documentation with findings, risk ratings, and remediation recommendations.

05

Implementation Support

We help implement recommendations including labeling, PPE selection, and system modifications.

06

Compliance Verification

Final review ensures full alignment with DEWA regulations and international standards.

FAQ

Common Questions

What is protective devices testing services | carelabz.com?

Protective Devices Testing Services | Carelabz.com is a critical component of electrical safety and compliance. Our team follows IEEE 1584, NFPA 70E, and DEWA standards to deliver thorough, actionable results for your facility.

Why is protective devices testing services | carelabz.com important?

Regular protective devices testing services | carelabz.com helps identify potential hazards, ensures regulatory compliance with DEWA requirements, and protects personnel and equipment from electrical incidents.

How often should protective devices testing services | carelabz.com be performed?

Industry best practice recommends conducting protective devices testing services | carelabz.com every three to five years, or after any major system modification. DEWA may require more frequent assessments for certain facility types.

Get Started

Need This Service?

Our engineering team is ready to help with your electrical safety requirements.