Leakage current is the current that streams from either DC or AC circuit in an electrical system to the frame, or to the earth or ground, and can be either from the output or input. The current will stream through other pathways such as the human body, if the equipment is not properly earthed. This might also occur if the ground is ineffective or is intruded unintentionally or intentionally.
Electrical system usually consists of a grounding technique that offers shield against a shock hazard if an insulation fault occurs. The grounding system comprises of a grounding rod that connects the instrument to the earth. If ever a disastrous failure of insulation between power line and conductive parts occur, the voltage will be pushed to ground. The current that is created as a result of this event will flow, causing a circuit breaker to open or a fuse to blow thus avoiding a shock hazard.
Clearly, a shock hazard prevails if the earth or ground connection is intruded, either accidentally or intentionally. The possibility for a shock might be larger than assumed if there is case of leakage currents. Even in the scenario of no insulation failure, intrusion of leakage currents streaming through the grounding rod still pose a threat of electric shock to somebody coming in contact with the ungrounded system and ground at the same time.
This is a huge concern when it comes to the field of medical applications, where a patient might be the receiver of the electric shock. A shock can be even fatal if the patient is weak or unconscious, or if the current flows to internal organs. The two layered insulation offered in non-grounded equipment ensures protection. The security in this scenario is made sure because both coats of insulation are not likely to collapse together. Nevertheless, the situations that leads to leakage currents still exists and must be taken into account.
Hence, how can you eradicate or reduce the outcomes of leakage current? Measure the leakage current and then recognise the cause.
| Type of Equipment | Maximum Leakage Current |
| Class I | 0.75mA for hand held devices |
| 3.5mA for other devices | |
| Class II | 0.25mA |
| Class III | No hazardous voltages |
Leakage current clamp meter is used to measure leakage current. They are similar to the clamp meters utilised for finding load currents, but gives considerably better results when quantifying currents less than 5mA. Generally clamp meters wouldn’t register such small currents. After we position the jaws of a clamp meter around a conducting rod or wire, the current reading is taken, and the value depends upon the intensity of the alternating electromagnetic field around the conductor. The clamp meter will identify the magnetic field around conductors like a wire armor cable, single core cable, a water pipe etc. The paired neutral and phase conductors of a single-phase circuit, or all live conductors of a three-phase circuit.
Our Process
We discuss your facility requirements, compliance goals, and project timeline.
Our engineers gather system data, single-line diagrams, and equipment specifications on-site.
We perform the study using industry-standard software and IEEE/IEC methodologies.
You receive actionable documentation with findings, risk ratings, and remediation recommendations.
We help implement recommendations including labeling, PPE selection, and system modifications.
Final review ensures full alignment with DEWA regulations and international standards.
FAQ
Electrical system usually consists of a grounding technique that offers shield against a shock hazard if an insulation fault occurs. The grounding system comprises of a grounding rod that connects the instrument to the earth. If ever a disastrous failure of insulation between power line and conduct.
* A meter specially designed for measuring leakage currents is used. * The current streaming through the ground rod is quantified by attaching the meter in series with the earthing connection. * For information processing equipment, the ground connection is opened and the current flowing to the neu.
Leakage current clamp meter is used to measure leakage current. They are similar to the clamp meters utilised for finding load currents, but gives considerably better results when quantifying currents less than 5mA. Generally clamp meters wouldn’t register such small currents. After we position the.